How do you avoid lift lines in architectural concrete?
Active use of the vibrator and deep penetration into the preceding lift is the key to elimination of lift lines. If vertical construction joints are placed reasonably close together the horizontal distance spanned by each lift will be smaller and problems associated with long periods of time between placements of two successive lifts will be minimized.